Why choose ZICOTEC?

Air to Direct Peltier assembly module

Model: ID-330-24-AD

The ID-330-24-AD is a standard Thermoelectric Assembly in Zicotec that heat dissipation is forced air on hot sides, and direct connective on cold side. It provides active thermal solution to cooling objects. The hot side uses one high performance heat sink with brand name fan to realize lower thermal resistance. The cold side is contact to customer heat source or cooling target. The brand name thermoelectric modules are custom designed to achieve a high coefficient of performance to minimize power consumption. Custom configurations and moisture protection options are available.

PRODUCT SPECIFICATIONS

1.Technical Specifications

Specifications

Production application

Indoor

Cooling power Max (w) *

329.8w, @ 35°C, dT=0°C

Operation Voltage (VDC)

24VDC (Max 15VDC)

TEM Current (A)

Normal 13.2A, Initial 14.5A

Fan Rated Current (A)

Hot: 1.43A,

Total power consumption (w)*

350.4w, (TEM: 316.1w, Fan: 34.3w)

COP *

>0.9, (dT = 0°C)

TEM Resistance (Ω, ±10%, 23°C)

1.24-1.38-1.52

Performance Tolerance  (±%)

±10%

Hold side thermal dissipated

Force convection by Axial fan

Cold side thermal dissipated

Direct convection by Aluminum block

Over temperature (hot side)

75°C

Operation temperature range

-10°C to 55°C

IP Level

None

Fan MTBF

70,000hours @40°C, 65%RH

Noise level

<63dB(A)

Certification Compliance

RoHS

Weight (kg)

6.3

Notes:

– “ * “ Based on operation voltage 24VDC.

– The above performance of unit is depended on Zicotec technology design and Lab test result.

Performance Curve

Dimension information (unit:mm)

THERMAL DESIGN

Thermal design simulation is beneficial to the design and development of Thermoelectric cooling unit. It helps engineer to work out a Thermoelectric Assembly in a short time.

The boundary conditions in simulation as below,

The ambient temperature in 35°C, the operation voltage 24VDC. A dummy heater generated 190w attached to cold side of Thermoelectric Assembly unit. The simulation result requires thermoelectric cooling unit to maintain the dummy heater 35°C.

Testing &Lab

Thermoelectric Assembly can be validated by real cooling performance testing. We used a standard enclosure for Air to Air series, a Standard dummy heater for Air to Direct series and Air to Liquid.

Installation Requirement

1. Install and use the unit in indoor only.

2.Use 4-M4 mechanical screw, tooth washers and flat washers for installation.

3.Enough insulation to cold side is important, it will reduce the heat leak, and condensation water in cold side

4.Input power is less than 26.4VDC.

5.Clean the fan impeller and heat sink to keep the good heat transfer during maintenance. ( Brush or air to remove the dust only, No water)

6.Use a fuse in line to protect input power lines.

Safety & Warning