Why choose ZICOTEC?

Air to Direct Peltier assembly module

ID-120-24-AL

The ID-120-24-AL is a standard Thermoelectric Assembly in Zicotec that heat dissipation is forced air on hot sides, and Liquid cooling connective on cold side. It provides active thermal solution to cooling objects. The hot side uses one high performance heat sink with brand name fan to realize lower thermal resistance. The cold side is liquid exchanger. The brand name thermoelectric modules are custom designed to achieve a high coefficient of performance to minimize power consumption. Custom configurations and moisture protection options are available.

PRODUCT SPECIFICATIONS

1.Technical Specifications

Specifications

Production application

Indoor

Cooling power Max (w) *

123w, @ 35°C, dT=0°C

Operation Voltage (VDC)

24VDC (Max 26.4VDC)

TEM Current (A)

Normal 5.13A, Initial5.7A

Fan Rated Current (A)

Hot: 0.4A,

Total power consumption (w)*

132.7w, (TEM: 123.1w, Fan: 9.6w)

COP *

>0.9, (dT = 0°C)

TEM Resistance (Ω, ±10%, 23°C)

3.06-3.40-3.74

Performance Tolerance  (±%)

±10%

Hold side thermal dissipated

Force convection by Axial fan

Cold side thermal dissipated

Liquid transfer by Aluminum exchanger

Over temperature (hot side)

75°C

Operation temperature range

-10°C to 55°C

IP Level

None

Fan MTBF

70,000hours @40°C, 65%RH

Noise level

<55dB(A)

Certification Compliance

RoHS

Weight (kg)

3.7

Notes:

– “ * “ Based on operation voltage 24VDC.

– The above performance of unit is depended on Zicotec technology design and Lab test result.

Performance Curve

Dimension information (unit:mm)

THERMAL DESIGN

Thermal design simulation is beneficial to the design and development of Thermoelectric cooling unit. It helps engineer to work out a Thermoelectric Assembly in a short time.

The boundary conditions in simulation as below,

The ambient temperature in 35°C, the operation voltage 24VDC. A dummy heater exchanger generated 120w inside liquid exchanger. The simulation result requires thermoelectric cooling unit to maintain 35°C inside the exchanger, flow rate 4L/min.

Testing &Lab

Thermoelectric Assembly can be validated by real cooling performance testing. We used a standard enclosure for Air to Air series, a Standard dummy heater for Air to Direct series and Air to Liquid.

Installation Requirement

1. Install and use the unit in indoor only.

2.Enough insulation to cold side is important, it will reduce the heat leak, and condensation water in cold side.

3.Suitable cabinet cutout size 124x250mm. Enough insulation around cabinet is important. It will be helpful to improve cooling capacity. Recommend the thickness of insulation >10mm

3.Input power is less than 26.4VDC.

4.Clean the fan impeller and heat sink to keep the good heat transfer during maintenance. (Brush or air to remove the dust only, No water)

5.Use a fuse in line to protect input power lines.

Safety & Warning

You May Also Be Interested

Discover more matching thermal management products and integrated thermoelectric assemblies to satisfy different precision temperature control demands. Contact our engineering team if you require customized solutions..

ID-130-24-AD

Max cooling power 130W

ID-190-24-AD

Max cooling power 190W

ID-330-24-AD

Max cooling power 330W